Download PDF
Editorial  |  Open Access  |  31 Jul 2022

Mesh or no mesh in anti-reflux surgery

Views: 939 |  Downloads: 664 |  Cited:  1
Mini-invasive Surg 2022;6:46.
10.20517/2574-1225.2022.46 |  © The Author(s) 2022.
Author Information
Article Notes
Cite This Article

INTRODUCTION & BACKGROUND

History of evidence accumulation for anti-reflux surgery

Surgery against refractory gastroesophageal reflux disease and hiatal hernia depends on hiatal closure and prevention of either recurrent herniation or symptoms of ongoing reflux[1]. In the past few decades in anti-reflux surgery (ARS), attempts have been made to judge the quality of the evidence underlying the practices of surgeons in ARS. In the second half of the twentieth century, the evidence base for many practices in ARS was poor[1]. One suggestion to augment hiatal closure was the use of mesh, but its use was supported by mostly case series and reports until the turn of the century. Currently, the use of mesh is not universally accepted, and more studies have accumulated about the use of mesh in ARS[2,3].

Trends of mesh use in ARS

In a 2010 survey of members of the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES), mesh was commonly used in hiatal hernia repair (HHR) and the most commonly cited indication (45% of respondents) for mesh placement was the size of the hernia defect with 24% citing a size of 5 cm as the decision point[4]. The technique of placement was highly heterogeneous although an onlay technique in some fashion and suture fixation were most common[4]. In a similar survey of SAGES members in 2012, 77% of respondents at least selectively used mesh in HHR with the trend in the data suggesting that younger surgeons were more likely to use mesh than were older surgeons[5]. In both surveys of the SAGES community, mesh types were heterogeneous although biologic meshes were most commonly used[4,5]. Similar results were found in a survey of the European Association for Endoscopic Surgery (EAES) in 2015, with higher use of mesh at 92.1% of European surgeons at least selectively using mesh although mesh types differed with most surgeons preferring either polypropylene, polyester or PTFE meshes and only 27.9% using biologic meshes[6]. In registry analyses, these survey results are further expanded: mesh is used frequently but in less than half of ARS cases overall[7-10]. As for trends over time, in two National Surgery Quality Improvement Program (NSQIP) analyses between 2010-2015, the use of mesh remained stable over time at around 38%-43%[7,8]. In registry analyses including the second half of the last decade, however, results conflicted. In an NSQIP analysis between 2010-2017 of over 25,000 cases, mesh utilization decreased from 46.2% to 35.2%[9]. In a European analysis between 2010 - 2019, mesh utilization for axial HHR was stable at ~20%, for paraesophageal HHR mesh increased from 33% to 38.9%, and was stable for recurrent HHR at around 45%[10].

Professional society recommendations and directions

The heterogeneous practice patterns in ARS are reflected in recent reviews and in professional society guidelines. In the SAGES Guideline on general Surgical Treatment of GERD from 2021, mesh use is not discussed, but in its Guideline on Management of Hiatal Hernia Repair in 2013, mesh is recommended for large HH based on several randomized controlled trials (RCT), although long-term data is noted to be insufficient beyond the short follow-up interval of the available RCTs as of 2013[11,12]. In this chapter, we will review the most recent data underlying the subscription to mesh use in ARS as well as more specific considerations of mesh implementation in ARS.

Hiatal hernia repair

Highest level of data - the meta-analyses of suture vs. mesh in HHR

In general, mesh utilization in ARS is most relevant in HHR. Given the publication of several RCTs about mesh utilization in HHR since the most recent SAGES guidelines, multiple meta-analyses have subsequently been published [Table 1][13-25]. Although results from earlier meta-analyses might suggest benefits for mesh placement, it should be noted that most early studies include observational data. Two recent meta-analyses are consistent in evaluating the same 7 RCTs only (no observational data included), and both find no advantage to the use of mesh in HHR[13,14]. Caution in interpreting the meta-analytic data is advised as the RCTs included are heterogeneously conducted (see next section).

Table 1

Metanalyses on mesh use in HHR in reverse chronological order

Hernia recurrence in index procedureNeed for reoperationSymptomatic improvementOverall complication
AuthorsRCTObsnFavoredFavoredFavoredFavored
Angeramo et al. (2022)[13]70735NeitherNeither---Suture
Petric et al. (2022)[14]70735Neither---NeitherNeither
Rausa et al. (2021)[15]891857Mesh------Neither
Campos et al.(2020)[16]62520NeitherNeither---Neither
Memon et al.(2019)[17]50478NeitherMesh---Neither
Sathasivam et al. (2019)[18]45942MeshNeither---Neither
Zhang et al. (2017)[19]491474Mesh---MeshNeither
Memon et al.(2016)[20]40406NeitherMesh---Neither
Tam et al. (2016)[21]3101194MeshNeither------
Huddy et al.(2016)[22]45676MeshMesh---Neither
Antoniou et al.(2015)[23]23295Mesh---------
Muller-Stitch et al. (2015)[24]39915Neither------Mesh
Antoniou et al.(2012)[25]30267Mesh---------

A granular look at the RCTs conduct on mesh utilization in HHR

As can be seen in the table below, the heterogeneity of available RCTs studying mesh placement in HHR since 2000 is noteworthy [Table 2][26-32], especially when considering years of follow-up and the type of mesh used. Two studies used biologic meshes and the other five used non-absorbable meshes. Additionally, the studies frequently define inclusion size for HH differently. Of note, the two largest, most recent studies both show no definite advantage with mesh utilization[26,27]. This likely accounts for the differences seen in the most recent meta-analyses compared to those from prior years.

Table 2

RCTs evaluating mesh vs. suture in HHR, in reverse chronological order

AuthorsnFollow-upMesh RecurrenceOverall satisfactionOverall complicationReoperation
Watson
et al. (2020)[26]
1265 yearsSIS (absorbable) or polypropylene (non-absorbable)NeitherNeither------
Analatos
et al. (2020)[27]
1593 yearsPTFE (non-absorbable)NeitherNeitherNeitherNeither
Ilyashenko et al. (2018)[28]984.5 yearsPolyester-polylactic composite (non-absorbable)MeshMeshNeitherNeither
Oor (2018)[29]721 yearpolypropylene (non-absorbable)NeitherNeitherNeitherNeither
Oelschlager et al. (2011)[30]7258 monthsSIS (absorbable)NeitherNeitherNeitherNeither
Granderath et al. (2005)[31]1001 yearpolypropylene (non-absorbable)MeshNeitherNeitherNeither
Frantzides et al. (2002)[32]722.5 yearsPTFE (non-absorbable)Mesh---NeitherMesh

Observational data in mesh placement during HHR

Although many observational studies have been published on mesh use in HHR, few add to the RCTs and meta-analyses discussed previously. Heterogeneity is the rule with little standardization across the board, but a few observational studies stand out. The largest observational study featured 795 patients; the mesh-repair group featured mostly biologic mesh[33]. This study agreed with the findings of metanalyses of RCTs in that there was no long-term difference in recurrence between mesh-based and suture-based HHR[33]. In the only study of any style to our knowledge that discusses financial cost, several biologic meshes are compared and the lowest recurrence rate is shown for human tissue matrix at 6 months but not at longer intervals[34]. With respect to cost in this study, porcine tissue matrix is the most costly and biosynthetic mesh is the least costly, but no cost comparison was made with the non-absorbable meshes or suture-based repair[34].

Other considerations in anti-reflux surgery

Gastroesophageal reflux disease without HH

In general, although when considering mesh usage in ARS one is discussing HHR, mesh can be used in non-HH-related ARS. In the only (small, n = 50) RCT to our knowledge in non-HH-related ARS comparing mesh- to non-mesh repairs, Muller-Stich et al. compared laparoscopic mesh-augmented hiatoplasty with cardiophrenicopexy (LMAH-C) with laparoscopic Nissen fundoplication (LNF) in patients with GERD but excluded those with Type II-IV HH[35]. Considering endoscopy findings and symptom scores as primary endpoints, they showed that treatment failure with higher reflux-related symptom scores and esophagitis findings was worse in the LMAH-C arm compared to LNF[35]. Although this is a demonstration of improved symptom control in non-HH-related ARS without the use of mesh, it is not clear that the lack of mesh is what was operative in this case as two different operations were compared independent of the mesh use or non-use: a gastropexy vs. a fundoplication. Generally, few data exist about mesh- vs. non-mesh repairs during non-HH-related ARS.

Reoperative anti-reflux surgery

Little data exists comparing mesh- and non-mesh-based repairs of reoperative ARS. Many surgeons consider reoperation an indication of mesh usage, and so perhaps the lack of data owes to the suspected lack of equipoise[4,9]. Nevertheless, in the only comparative study of mesh use in reoperative ARS - essentially a case series that discusses the use of mesh or not in reoperative ARS - Desai et al. found similar re-reoperation rates (16% vs. 20%) in mesh-based and non-mesh-based repairs of failed HHR (n = 82)[36]. Additionally, some of the RCTs for HHR include reoperative HHR, but none provide subgroup analysis of this population[27]. In general, the use of mesh in reoperative ARS has not been sufficiently studied.

Complicated HHs

Almost no data exist to guide the surgeon in choosing how to operate on the difficult population that presents with acute complicated HH, including gastric volvulus, perforation, or obstruction[3]. No comparative studies comparing mesh and non-mesh-based repairs in complicated HH are available.

Reasons not to use mesh

Finally, there are particular risks to the use of mesh not reflected in the apparently benign results in which no difference in complication rates is seen in mesh-based and non-mesh-based arms of RCTs in ARS. Mesh erosion is a feared complication in which the mesh burrows into the esophagus. Mesh erosion can present with dysphagia, abdominal pain, fistula, reduced oral intake, odynophagia, or weight loss. In a recent systematic review, the risk of this complication is about 0.035% of all ARS cases in which mesh is used, and non-biologic mesh is the more frequently associated culprit, with the complication generally occurring within 5 years of the procedure[37].

Though perhaps less often considered, there is a more common reason to avoid mesh if it does not benefit the patient: cost. Although the dollars-and-cents cost of mesh usage was not reported in any of the RCTs and few observational studies, mesh has an obvious cost on top of the simple sutures that would otherwise be used for crural approximation during ARS. In the study cited previously, several biologic meshes are compared and the costs vary but do not seem to affect the overall charge[34]. Aside from that report, however, very few data exist as to the financial cost-benefit analysis of mesh usage in ARS.

CONCLUSIONS

Although the data suffers from biases including heterogeneity in definition, materials applied in mesh-based repairs, follow-up duration, and drop-out, there is little evidence to recommend the routine use of mesh in anti-reflux surgery and a lack of strong evidence to promote selective mesh use, even for commonly cited indications like the large size of hernia or crural tension. Mesh usage for anti-reflux surgery in the United States and Europe remains prevalent, with more than 75% of surgeons selectively using mesh augmentation in 35%-40% of their cases.

DECLARATIONS

Authors’ contributions

Made substantial contributions to conception and design of chapter, analyzing available data, and performing interpretation: Bitner DP

Reviewed presented data, as well as provided administrative, technical, and material support: Filicori F

Availability of data and materials

Not applicable.

Financial support and sponsorship

IPAL is supported by private donations and institutional internal funding.

Conflicts of interest

Dr. Filicori has consulting affiliations with Active Surgical and Boston Scientific.

Dr. Bitner has consulting affiliation with Deep Surgery. 

Ethical approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Copyright

© Authors 2022.

REFERENCES

1. Neufeld M, Graham A. Levels of evidence available for techniques in antireflux surgery. Dis Esophagus 2007;20:161-7.

2. Currie AC, Penney N, Kamocka A, Singh P, Abbassi-Ghadi N, Preston SR. Systematic review on reporting of components and outcomes in randomized clinical trials of paraoesophageal hernia mesh repair. Br J Surg 2021;108:256-64.

3. Laxague F, Sadava EE, Herbella F, Schlottmann F. When should we use mesh in laparoscopic hiatal hernia repair? Dis Esophagus 2021;34:doaa125.

4. Frantzides CT, Carlson MA, Loizides S, et al. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc 2010;24:1017-24.

5. Pfluke JM, Parker M, Bowers SP, Asbun HJ, Daniel Smith C. Use of mesh for hiatal hernia repair: a survey of SAGES members. Surg Endosc 2012;26:1843-8.

6. Furnée EJB, Smith CD. The use of mesh in laparoscopic large hiatal hernia repair: a survey of European surgeons. Surg Endosc 2015;25:307-11.

7. Skancke M, Brody F, Haskins IN, Amdur R, Schoolfield C. Impact of operative times and mesh utilization on paraesophageal hernia repair: analysis of 30-day outcomes from the American college of surgeons national surgical quality improvement project database. J Laparoendosc Adv Surg Tech A 2019;29:303-8.

8. Schlottmann F, Strassle PD, Patti MG. Laparoscopic paraesophageal hernia repair: utilization rates of mesh in the USA and short-term outcome analysis. J Gastrointest Surg 2017;21:1571-6.

9. Schlosser KA, Maloney SR, Prasad T, Augenstein VA, Heniford BT, Colavita PD. Mesh reinforcement of paraesophageal hernia repair: trends and outcomes from a national database. Surgery 2019;166:879-85.

10. Köckerling F, Zarras K, Adolf D, et al. What is the reality of hiatal hernia management? Front Surg 2020;7:584196.

11. Slater BJ, Dirks RC, McKinley SK, et al. Guidelines for the surgical treatment of gastroesophageal reflux (GERD). Surg Endosc 2021;35:4903-17.

12. Kohn GP, Price RR, Demeester SR, et al. Guidelines for the management of hiatal hernia. Surg Endosc 2013;27:4409-28.

13. Angeramo CA, Schlottmann F. Laparoscopic paraesophageal hernia repair: to mesh or not to mesh. Systematic review and meta-analysis. Ann Surg 2022;275:67-72.

14. Petric J, Bright T, Liu DS, Wee Yun M, Watson DI. Sutured versus mesh-augmented hiatus hernia repair: a systematic review and meta-analysis of randomized controlled trials. Annals of Surgery 2022;275:e45-51.

15. Rausa E, Manfredi R, Kelly ME, et al. Prosthetic reinforcement in hiatal hernia repair, does mesh material matter? J Laparoendosc Adv Surg Tech A 2021;31:1118-23.

16. Campos V, Palacio DS, Glina F, Tustumi F, Bernardo WM, Sousa AV. Laparoscopic treatment of giant hiatal hernia with or without mesh reinforcement: a systematic review and meta-analysis. Int J Surg 2020;77:97-104.

17. Memon MA, Siddaiah-Subramanya M, Yunus RM, Memon B, Khan S. Suture cruroplasty versus mesh hiatal herniorrhaphy for large hiatal hernias (HHS): an updated meta-analysis and systematic review of randomized controlled trials. Surg Laparosc Endosc Percutan Tech 2019;29:221-32.

18. Sathasivam R, Bussa G, Viswanath Y, et al. “Mesh hiatal hernioplasty” versus “suture cruroplasty” in laparoscopic para-oesophageal hernia surgery; a systematic review and meta-analysis. Asian J Surg 2019;42:53-60.

19. Zhang C, Liu D, Li F, et al. Systematic review and meta-analysis of laparoscopic mesh versus suture repair of hiatus hernia: objective and subjective outcomes. Surg Endosc 2017;31:4913-22.

20. Memon MA, Memon B, Yunus RM, Khan S. Suture cruroplasty versus prosthetic hiatal herniorrhaphy for large hiatal hernia: a meta-analysis and systematic review of randomized controlled trials. Ann Surg 2016;263:258-66.

21. Tam V, Winger DG, Nason KS. A systematic review and meta-analysis of mesh vs suture cruroplasty in laparoscopic large hiatal hernia repair. The American Journal of Surgery 2016;211:226-38.

22. Huddy JR, Markar SR, Ni MZ, et al. Laparoscopic repair of hiatus hernia: does mesh type influence outcome? Surg Endosc 2016;30:5209-21.

23. Antoniou SA, Müller-Stich BP, Antoniou GA, et al. Laparoscopic augmentation of the diaphragmatic hiatus with biologic mesh versus suture repair: a systematic review and meta-analysis. Langenbecks Arch Surg 2015;400:577-83.

24. Müller-stich BP, Kenngott HG, Gondan M, et al. Use of mesh in laparoscopic paraesophageal hernia repair: a meta-analysis and risk-benefit analysis. PLoS ONE 2015;10:e0139547.

25. Antoniou SA, Antoniou GA, Koch OO, Pointner R, Granderath FA. Lower recurrence rates after mesh-reinforced versus simple hiatal hernia repair: a meta-analysis of randomized trials. Surg Laparosc Endosc Percutan Tech 2012;22:498-502.

26. Watson DI, Thompson SK, Devitt PG, et al. Five year follow-up of a randomized controlled trial of laparoscopic repair of very large hiatus hernia with sutures versus absorbable versus nonabsorbable mesh. Ann Surg 2020;272:241-7.

27. Analatos A, Håkanson BS, Lundell L, Lindblad M, Thorell A. Tension-free mesh versus suture-alone cruroplasty in antireflux surgery: a randomized, double-blind clinical trial. Br J Surg 2020;107:1731-40.

28. Ilyashenko VV, Grubnyk VV, Grubnik VV. Laparoscopic management of large hiatal hernia: mesh method with the use of ProGrip mesh versus standard crural repair. Surg Endosc 2018;32:3592-8.

29. Oor JE, Roks DJ, Koetje JH, et al. Randomized clinical trial comparing laparoscopic hiatal hernia repair using sutures versus sutures reinforced with non-absorbable mesh. Surg Endosc 2018;32:4579-89.

30. Oelschlager BK, Pellegrini CA, Hunter JG, et al. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. Journal of the American College of Surgeons 2011;213:461-8.

31. Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation preliminary results of a prospective randomized functional and clinical study. Arch Surg 2005;140:40-8.

32. Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 2002;137:649-52.

33. Tam V, Luketich JD, Levy RM, et al. Mesh cruroplasty in laparoscopic repair of paraesophageal hernias is not associated with better long-term outcomes compared to primary repair. Am J Surg 2017;214:651-6.

34. Armijo PR, Krause C, Xu T, Shostrom V, Oleynikov D. Surgical and clinical outcomes comparison of mesh usage in laparoscopic hiatal hernia repair. Surg Endosc 2021;35:2724-30.

35. Müller-Stich BP, Linke GR, Senft J, et al. Laparoscopic mesh-augmented hiatoplasty with cardiophrenicopexy versus laparoscopic Nissen fundoplication for the treatment of gastroesophageal reflux disease: a double-center randomized controlled trial. Ann Surg 2015;262:721-5; discussion 725.

36. Desai AA, Alemayehu H, Dalton BG, et al. Review of the experience with re-operation after laparoscopic Nissen fundoplication. Journal of Laparoendoscopic & Advanced Surgical Techniques 2016;26:140-3.

37. Spiro C, Quarmby N, Gananadha S. Mesh-related complications in paraoesophageal repair: a systematic review. Surg Endosc 2020;34:4257-80.

Cite This Article

Editorial
Open Access
Mesh or no mesh in anti-reflux surgery
Daniel P. BitnerDaniel P.  Bitner, Filippo Filicori

How to Cite

Bitner, D. P.; Filicori, F. Mesh or no mesh in anti-reflux surgery. Mini-invasive. Surg. 2022, 6, 46. http://dx.doi.org/10.20517/2574-1225.2022.46

Download Citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click on download.

Export Citation File:

Type of Import

Tips on Downloading Citation

This feature enables you to download the bibliographic information (also called citation data, header data, or metadata) for the articles on our site.

Citation Manager File Format

Use the radio buttons to choose how to format the bibliographic data you're harvesting. Several citation manager formats are available, including EndNote and BibTex.

Type of Import

If you have citation management software installed on your computer your Web browser should be able to import metadata directly into your reference database.

Direct Import: When the Direct Import option is selected (the default state), a dialogue box will give you the option to Save or Open the downloaded citation data. Choosing Open will either launch your citation manager or give you a choice of applications with which to use the metadata. The Save option saves the file locally for later use.

Indirect Import: When the Indirect Import option is selected, the metadata is displayed and may be copied and pasted as needed.

About This Article

Special Issue

This article belongs to the Special Issue Foregut Disease: Minimally Invasive and Innovation Therapeutics
© The Author(s) 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, sharing, adaptation, distribution and reproduction in any medium or format, for any purpose, even commercially, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Data & Comments

Data

Views
939
Downloads
664
Citations
1
Comments
0
0

Comments

Comments must be written in English. Spam, offensive content, impersonation, and private information will not be permitted. If any comment is reported and identified as inappropriate content by OAE staff, the comment will be removed without notice. If you have any queries or need any help, please contact us at support@oaepublish.com.

0
Download PDF
Share This Article
Scan the QR code for reading!
See Updates
Contents
Figures
Related
Mini-invasive Surgery
ISSN 2574-1225 (Online)
Follow Us

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/