REFERENCES
1. McClellan WT, Schessker MJ, Ruch DS, Levin LS, Goldner RD. A knotless flexor tendon repair technique using a bidirectional barbed suture: an ex vivo comparison of three methods. Plast Reconstr Surg 2011;128:e322-7.
3. Strickland JW. Development of flexor tendon surgery: twenty-five years of progress. J Hand Surg 2000;25:214-35.
4. Jordan MC, Hölscher-Doht S, Jakubietz MG, Jakubietz RG, Meffert RH, Schmidt K. Suture material for flexor tendon repair: 3-0 V-Loc versus 3-0 Stratafix in a biomechanical comparison ex vivo. J Orthop Surg Res 2014;9:72.
5. Gussous YM, Zhao C, Amadio P, An KN. The resurgence of barbed suture and connecting devices for use in flexor tendon tenorrhaphy. Hand 2011;6:268-75.
6. Joyce CW, Sugrue C, Chan JC, Delgado L, Zeugolis D, Carroll SM, Kelly JL. A barbed suture repair for flexor tendons: a novel technique with no exposed barbs. Plast Reconstr Surg Glob Open 2014;2:e237.
7. Naleway SE, Lear W, Kruzic JJ, Maughan CB. Mechanical properties of suture materials in general and cutaneous surgery. J Biomed Mater Res B Appl Biomater 2015;103:735-42.
8. Viinikainen A, Goransson H, Huovinen K, Kellomaki M, Rokkanen P. A comparative analysis of the biomechanical behavior of five flexor tendon core sutures. J Hand Surg Br 2004;29:536-43.
9. Parikh PM, Davison SP, Higgins JP. Barbed suture tenorrhaphy: an ex vivo biomechanical analysis. Plast Reconstr Surg 2009;124:1551-8.
10. Rawson S, Cartmell S, Wong J. Suture techniques for tendon repair; a comparative review. Muscles Ligaments Tendons J 2013;3:220-8.
11. Kanz BN, Morris RP, Lewis T, Panchbhavi VK. Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model. Foot Ankle Special 2014;7:176-81.
12. Marrero-Amadeo IC, Chauhan A, Warden SJ, Merrell GA. Flexor tendon repair with a knotless barbed suture: a comparative biomechanical study. J Hand Surg 2011;36:1204-8.
13. Lin TE, Lakhiani C, Lee MR, Saint-Cyr M, Sammer DM. Biomechanical analysis of knotless flexor tendon repair using large-diameter unidirection barbed suture. Hand 2013;8:315-9.
14. Vizesi F, Jones C, Lotz N, Gianoutsos M, Walsh WR. Stress relaxation and creep: viscoelastic properties of common suture materials used for flexor tendon repair. J Hand Surg 2008;33:241-6.
15. Von Fraunhofer JA, Storey RS, Stone IK, Masterson BJ. Tensile strength of suture materials. J Biomed Mat Res 1985;19:595-600.
16. Von Fraunhofer J, Storey R, Masterson B. Tensile properties of suture materials. Biomaterials 1988;9:324-7.
17. Greenwald D, Shumway S, Albear P, Gottlieb L. Mechanical comparison of 10 suture materials before and after in vivo incubation. J Surg Res 1994;56:372-7.
18. Ingle N, King M. Optimizing the tissue anchoring performance of barbed sutures in skin and tendon tissues. J Biomech 2010;43:302-9.
19. Peltz TS, Haddad R, Scougall PJ, Gianoutsos MP, Bertollo N, Walsh WR. Performance of a knotless four-strand flexor tendon repair with a unidirectional barbed suture device: a dynamic ex vivo comparison. J Hand Surg Eur Vol 2014;39:30-9.
20. Ingle N, King M, Zikry M. Finite element analysis of barbed sutures in skin and tendon tissues. J Biomech 2010;43:879-86.
21. Zeplin PH, Zahn RK, Meffert RH, Schmidt K. Biomechanical evaluation of flexor tendon repair using barbed suture material: a comparative ex vivo study. J Hand Sur 2011;36:446-9.
22. Trail I, Powell E, Noble J. An evaluation of suture materials used in tendon surgery. J Hand Sur Br 1989;14:422-7.
23. Dennis C, Sethu S, Nayak S, Mohan L, Morsi YY, Manivasagam G. Suture materials - current and emerging trends. J Biomed Mat Res A 2016;104:1544-59.
24. Williams J. Visco-elastic and thermal effects on crack growth in PMMA. Inter J Fract Mech 1972;8:393-401.
25. Knauss WG. Delayed failure - the Griffith problem for linearly viscoelastic materials. Inter J Fract Mech 1970;6:7-20.
26. Knauss WG. On the steady propagation of a crack in a viscoelastic sheet: experiments and analysis. In: Deformation and Fracture of High Polymers. Springer; 1973. pp. 501–41.
27. Mac Cartney LN. Crack growth laws for a variety of variety of viscoelastic solid using energy and COD fracture criteria. Inter J Fract 1979;15:31-40.
28. Ward SR, Loren GJ, Lundberg S, Lieber RL. High stiffness of human digital flexor tendons is suited for precise finger positional control. J Neurophysiol 2006;96:2815-8.
29. Sapienza A, Yoon HK, Karia R, Lee SK. Flexor tendon excursion and load during passive and active simulated motion: a cadaver study. J Hand Sur Eur Vol 2013;38:964-71.
30. Schapery R. A theory of crack initiation and growth in viscoelastic media. Inter J Fract 1975;11:141-59.
31. Schapery R. A theory of crack initiation and growth in viscoelastic media II. Approximate methods of analysis. Inter J Fract 1975;11:369-88.
32. Schapery R. A theory of crack initiation and growth in viscoelastic media. III- Analysis of continuous growth. Inter J Fract 1975;11:549-62.
33. Schapery R. A method for predicting crack growth in nonhomogeneous viscoelastic media. Inter J Fract 1978;14:293-309.
34. McCartney L. Crack propagation, resulting from a monotonic increasing applied stress, in a linear viscoelastic material. Inter J Fract 1977;13:641-54.
35. McCartney L. Crack propagation in linear viscoelastic solids: some new results. Inter J Fract 1978;14:547-54.
37. Christensen R. Lifetime predictions for polymers and composites under constant load. J Rheol 1981;25:517-28.
38. Christensen R, Glaser R. The application of kinetic fracture mechanics to life prediction for polymeric materials. J Appl Mech 1985;52:1-5.