Download PDF
Case Report  |  Open Access  |  25 Sep 2017

Bjork-Shiley tricuspid valve endocarditis thirty years after implantation

Views: 3383 |  Downloads: 890 |  Cited:  0
Vessel Plus 2017;1:151-4.
10.20517/2574-1209.2017.06 |  © 2017 OAE Publishing Inc.
Author Information
Article Notes
Cite This Article

Abstract

The Bjork-Shiley valve has been in use since 1971. Its longevity has been well reported in the literature. The study report a case of the Bjork-Shiley valve implanted in a young man, who presents with bacterial endocarditis 30 years after implantation of the valve. Transthoracic echocardiography showed vegetations in the mechanical tricuspid valve, with positive blood cultures csonfirming the diagnosis. Artificial valves increase the risk of contracting endocarditis but this is the first report of a case of bacterial endocarditis occurring in a mechanical tricuspid valve replacement 30 years after the initial implantation.

Keywords

Mechanical valve, tricuspid valve stenosis, endocarditis

Introduction

The choice of valve implantation is a complex decision that is usually made after consultation with the family and the patient. In the era of transcatheter valve insertions, the decision may start favouring the bioprosthetic valves. Recent updates in pericardial valves and anti-calcification techniques have also resulted in more durable bioprosthetic valves with outcomes surpassing 20 years expected, although this is yet to be seen in younger patients’ due to the preference for a more durable mechanical valve given the potential longevity offered. Mechanical valves are also likelier to be used in the setting of mitral stenosis which almost invariably occurs alongside atrial fibrillation which is an indication for anticoagulation in itself. Point of care testing for anticoagulation efficiency with allied health professional led international normalised ratio clinics have been in favour of mechanical valves but the introduction of direct oral anti-coagulants (DOACs) for first line atrial fibrillation treatment has brought a paradigm shift favouring bioprosthetic valves. Tricuspid valve replacements however, are less common compared to the mitral valve, thereby lacking a consensus on the optimal choice of valve. As the right heart is a lower pressure system, the stasis of blood causing increase thrombogenicity may favour the use of tissue based valves. Artificial valves do predispose patients to an increased risk of bacterial endocarditis. This can be attributed to adherent surfaces of suture lines, turbulent flows and nidus for infections in microthrombi produced especially in mechanical valves.

We present a case report of a patient who presented 30 years after his first operation with bacterial endocarditis.

Case report

A 48-year-old Caucasian male presented to our institution with fever, shortness of breath and increasing fatigability. His past medical history included a previous tricuspid valve replacement with a Bjork-Shiley tilting disc valve in 1986 due to endocarditis from an unknown origin and severe tricuspid valve regurgitation.

As part of his follow-up, he attended annual surveillance echocardiography clinics. A possible pannus forming around the mechanical valve prosthesis was noted on his latest scan. This extensively reduced the effective orifice area. As he was well and asymptomatic, a plan was made to repeat the echocardiogram in 6 months’ time. However, he became severely unwell following a urinary tract infection and required intravenous antibiotic therapy.

He was found collapsed and presented to the intensive care unit in our institute requiring mechanical ventilation. He had no pathognomonic signs of bacterial endocarditis such as splinter haemorrhages, Roth’s spots, Osler’s nodes and Janeway lesions. An urgent echocardiogram highlighted large prominent vegetations with severe tricuspid valve stenosis [Video 1]. Blood cultures were positive for Staphylococcus Aureus.

https://oaepublishstorage.blob.core.windows.net/ec0f49db-ded6-4f3e-83d9-ff88f949932a/2061.Video.1.mov
Video 1

[Video 1]

He had multiple episodes of non-sustained ventricular tachycardia. He later developed an acute kidney injury and the following a multidisciplinary team decision, he underwent an urgent redo-operation.

After right atriotomy, pannus and vegetation was observed on the mechanical valve were clearly visible [Figures 1 and 2]. The mechanical valve was explanted and replaced with a 31-mm bioprosthetic valve. His post-operative period was uneventful but for an episode of acute kidney injury which settled with intravenous fluids. He made a good recovery and was discharged on the 20th post-operative day. He was seen in the post-operative clinic after discharge and reports being well with no further complications.

Bjork-Shiley tricuspid valve endocarditis thirty years after implantation

Figure 1. Pannus formation on atrial (A) and ventricular (B) surface of the valve; the patient remained asymptomatic and compliant with warfarinisation with no thromboemboli event during the 30-year lifespan of the valve

Bjork-Shiley tricuspid valve endocarditis thirty years after implantation

Figure 2. Vegetation (arrow) on atrial surface of the valve from surgeon's view; the endocarditis was caused by pyelonephritis with Staphylococcus Aureus

Discussion

Tricuspid valve endocarditis is a well recognised disease with a wide spectrum of pathologies which is not limited to intravenous drug abuse and can be caused even by monitoring lines.[1] Up to 40% of prosthetic valve endocarditis is cause by Staphylococci infections.[2] Artificial valve endocarditis is also more common in the atrioventricular valve owing to reduced flow velocities across the valves particularly in the right side of the heart. Pannus growth tends to occur in the tissue valve interface and tracks along the suture lines as seen in our patient. However, encroachment into the valve orifice is uncommon. Pannus formation was the causes mechanical valve obstruction in about 10% of valves.[3]

Implantation of prosthetic valve in tricuspid position has been debated frequently in the literature with a consensus on bioprosthesis favouring mechanical valve due to the increased occurrence of valve-related events, especially the composite of thrombosis, embolism, and bleeding high risk of thrombosis when a mechanical valve is implanted in tricuspid position.[4,5] The management of thrombosis can be challenging and depending on patient clinical manifestation or degree of valvular obstruction the management can vary from observation to emergency operation.[6]

With the emergence of transcatheter technology, bioprosthetic valve implantation in the tricuspid position is an ideal alternative while future valve-in-valve implantation feasible in the event of valve failure.[7] To our knowledge there is no report of mechanical valve implantation lasting more than 30 years in the tricuspid position. The abovementioned patient had excellent compliance with anticoagulation therapy, thus explaining his mechanical valve longevity without any episodes of thrombosis. It has been observed that non-compliance with coumadin plays a pivotal role in thrombosis and valve malfunction.[4]

Bjork-Shiley tilting disc valves had a good clinical profile following decades of implantation. However, they became obsolete following the invention of more innovative mechanical valves with better profiles facilitated by double tilting discs. In 1979, the convexo-concave design of the Bjork-Shiley valve came under scrutiny as it was prone to fractures in the outflow strut. This resulted in the food and drug administration withdrawing approval of the 1986, around the time our patient had his valve implanted.[8]

Despite advancements in valve design and refinement in surgical techniques, the type of valve implantation (mechanical versus bioprosthesis) remains a dilemma among surgeons in all 4 valves positions. Although, patient autonomy dictates that they be given priority to choose the type of valve, a surgeons input is of paramount importance. The evolving technology has influenced the guidelines with rapid amendments and new published editions. Newer generations of mechanical valves with better performance with regards to amplitude and duration of regional backflow velocities across the mechanical valve as the main culprit for thrombosis are currently available.[9] DOACs may have a role in the mechanical valves of the future despite the findings of the recently published RE-ALIGN trial.[10] It may be a reality to have alternatives to coumadin therapy for mechanical valves in the near future.

Declarations

Authors’ contributions

Writing manuscript, operating surgeon: K. Shaikhrezai

Writing and reviewing manuscript: S.S.A. Singh

Reviewing manuscript: C. Spadaccio

Supervision and operating surgeon: S. Hunter

Financial support and sponsorship

None.

Conflicts of interest

There are no conflicts of interest.

Patient consent

Written consent was obtained from the patient preoperatively.

Ethics approval

Medical Photography was obtained with permission from the patient and the Local Clinical Governance Committee.

REFERENCES

1. Sundhu M, Mohapatra S, Arobelidze S, Gundelly P, Changarath Vijayan AK. Infective endocarditis in a patient with celiac disease after censtral venous catheter insertion. Cureus 2017;9:e1027.

2. Selton-Suty C, Célard M, Le Moing V, Doco-Lecompte T, Chirouze C, Iung B, Strady C, Revest M, Vandenesch F, Bouvet A, Delahaye F, Alla F, Duval X, Hoen B; AEPEI Study Group. Preeminence of staphylococcus aureus in infective endocarditis: a 1-year population-based survey. Clin Infect Dis 2012;54:1230-9.

3. Deviri E, Sareli P, Wisenbaugh T, Cronje SL. Obstruction of mechanical heart valve prostheses: clinical aspects and surgical management. J Am Coll Cardiol 1991;17:646-50.

4. Yaminisharif A, Alemzadeh-Ansari MJ, Ahmadi SH. Prosthetic tricuspid valve thrombosis: three case reports and literature review. J Tehran Heart Cent 2012;7:147-55.

5. Betancur-Gutiérrez A, Bayón-Fernández J, Má García-Rodríguez, García-Egido A, Garrote-Coloma C, Fernández-Vázquez F. Thrombosis of a mechanical tricuspid valve prosthesis resolved with fibrinolysis. Rev Esp Cardiol (Engl Ed) 2014;67:1064-6.

6. Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) ESC, Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Barón-Esquivias G, Baumgartner H, Borger MA, Carrel TP, De Bonis M, Evangelista A, Falk V, Iung B, Lancellotti P, Pierard L, Price S, Schäfers HJ, Schuler G, Stepinska J, Swedberg K, Takkenberg J, Von Oppell UO, Windecker S, Zamorano JL, Zembala M; European Association for Cardio-Thoracic Surgery (EACTS). Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 2012;33:2451-96.

7. Panaich SS, Eleid MF. Tricuspid valve-in-valve implantation for failing bioprosthetic valves: an evolving standard of care. Ann Transl Med 2016;4:410.

8. Blackstone EH. Could it happen again? the björk-shiley convexo-concave heart valve story. Circulation 2005;111:2717-9.

9. Chaux A, Gray RJ, Stupka JC, Emken MR, Scotten LN, Siegel R. Anticoagulant independent mechanical heart valves: viable now or still a distant holy grail. Ann Transl Med 2016;4:525.

10. Shazly A, Afifi A. RE-ALIGN: first trial of novel oral anticoagulant in patients with mechanical heart valves - the search continues. Glob Cardiol Sci Pract 2014;2014:88-9.

Cite This Article

Case Report
Open Access
Bjork-Shiley tricuspid valve endocarditis thirty years after implantation
Kasra Shaikhrezai, ... Steven Hunter

How to Cite

Shaikhrezai, K.; Singh S. S. A.; Spadaccio C.; Hunter S. Bjork-Shiley tricuspid valve endocarditis thirty years after implantation. Vessel. Plus. 2017, 1, 151-4. http://dx.doi.org/10.20517/2574-1209.2017.06

Download Citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click on download.

Export Citation File:

Type of Import

Tips on Downloading Citation

This feature enables you to download the bibliographic information (also called citation data, header data, or metadata) for the articles on our site.

Citation Manager File Format

Use the radio buttons to choose how to format the bibliographic data you're harvesting. Several citation manager formats are available, including EndNote and BibTex.

Type of Import

If you have citation management software installed on your computer your Web browser should be able to import metadata directly into your reference database.

Direct Import: When the Direct Import option is selected (the default state), a dialogue box will give you the option to Save or Open the downloaded citation data. Choosing Open will either launch your citation manager or give you a choice of applications with which to use the metadata. The Save option saves the file locally for later use.

Indirect Import: When the Indirect Import option is selected, the metadata is displayed and may be copied and pasted as needed.

About This Article

This is an open access article licensed under the terms of Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, as long as the original author is credited and the new creations are licensed under the identical terms.

Author Biographies

Mr. Kasra Shaikhrezai, MD, MSc, MRCS, FETCS, FRCS (C-Th), is a newly appointed consultant cardiac surgeon with a keen interest in mitral valve surgery. He finished his undergraduate degree in Kermanshah University of Medical Sciences and then worked at Harefield Hospital as a Senior House Officer. It was during this rotation he decided he would embark on a career in cardiac surgery. He underwent the Scottish National Training programme and served as the Scottish Trainee representative. He completed his MSc in advanced surgical practice in 2013 while working full time. He underwent a minimally invasive mitral valve and AF ablation fellowship at the Northern General Hospital in Sheffield in 2015 before his current appointment as of August 2017. He is also a clinical lecturer at the University of Glasgow. Outside medicine, his interests include travelling and cinematography.

Data & Comments

Data

Views
3383
Downloads
890
Citations
0
Comments
0
17

Comments

Comments must be written in English. Spam, offensive content, impersonation, and private information will not be permitted. If any comment is reported and identified as inappropriate content by OAE staff, the comment will be removed without notice. If you have any queries or need any help, please contact us at support@oaepublish.com.

0
Download PDF
Share This Article
Scan the QR code for reading!
See Updates
Contents
Figures
Related
Vessel Plus
ISSN 2574-1209 (Online)
Follow Us

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/

Portico

All published articles are preserved here permanently:

https://www.portico.org/publishers/oae/